Filter Results By:

Products

Applications

Manufacturers

Analog Input Output

Analog I/O are Devices that have the capability of sending and receiving analog signals.


Showing results: 61 - 75 of 376 items found.

  • PXIe-4162, 12-Channel, ±24 V, Precision PXI Source Measure Unit

    785680-01 - NI

    PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit - The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. It also features guard terminals to remove the effects of leakage currents and parasitic capacitances. Additionally, the PXIe-4162 can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4162 is ideal for a broad range of mixed-signal integrated circuits (ICs) in semiconductor production test.

  • PXIe-4309 , 28-Bit, 32-Channel, 2 MS/s, ±15 V Flexible Resolution PXI Analog Input Module

    784471-01 - NI

    28-Bit, 32-Channel, 2 MS/s, ±15 V Flexible Resolution PXI Analog Input Module—The PXIe-4309 samples up to 32 differential channels and multiplexes the analog input channels across eight simultaneously sampling ADCs. The module samples eight input channels up to 2 MS/s/ch (single channel per ADC), and 32 input channels up to 100 kS/s/ch (four channels per ADC). The module's flexible resolution ranges from 18 bits at 2 MS/s/ch to 28 bits at 2 S/s/ch. The module features on-board signal averaging and filtering, auto-zero measurement switching, and a chopping mode that uses a pair of channels to provide high levels of noise rejection and to enable accurate and repeatable nano-volt measurements.

  • PXIe-4357 , 20-Channel, 24-Bit PXI Temperature Input Module

    782118-01 - NI

    20-Channel, 24-Bit PXI Temperature Input Module—The NI PXIe‑4357 input module provides integrated data acquisition and signal conditioning for 2‑, 3‑, or 4‑wire resistance temperature detector (RTD) measurements. It offers both high-speed and high-resolution modes. It provides per channel software-programmable configurations and automatically scale measured data into engineering units.

  • PXIe-4464, 204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module

    783087-02 - NI

    204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module—The PXI‑4464 delivers simultaneous sampling on all channels. In addition, the PXI‑4464 includes built-in antialiasing filters that automatically adjust to your sampling rate, six software-selectable input gains ranges, and TEDS smart sensor support for error-free setup. The IEPE excitation circuit can deliver current for high-power sensors and strong data integrity over long sensor cable runs.

  • PXIe-4481, 24-Bit, 6-Channel, 1.25 MS/s/ch PXI Analog Input Module

    784278-01 - NI

    24-Bit, 6-Channel, 1.25 MS/s/ch PXI Analog Input Module—The PXIe‑4481 is an analog input module for higher bandwidth voltage measurements. The module offers analog and digital filtering for accurate frequency domain measurements. You also can select from four gain settings to configure your input range. For measuring sudden changes, such as high speed blast and pressure events, the PXIe-4481 can sample up to 20 MS/s per channel in time domain mode. The included NI-DAQmx driver simplifies hardware configuration and measurement.

  • PXIe-4464 , 204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module

    783087-01 - NI

    204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module—The PXI‑4464 delivers simultaneous sampling on all channels. In addition, the PXI‑4464 includes built-in antialiasing filters that automatically adjust to your sampling rate, six software-selectable input gains ranges, and TEDS smart sensor support for error-free setup. The IEPE excitation circuit can deliver current for high-power sensors and strong data integrity over long sensor cable runs.

  • PXIe-4480, 1.25 MS/s, 3.4 Hz AC/DC-Coupled, 6-Input PXI Sound and Vibration Module

    784277-01 - NI

    1.25 MS/s, 3.4 Hz AC/DC-Coupled, 6-Input PXI Sound and Vibration Module—The PXIe‑4480 is designed for high-bandwidth audio, acoustic, and vibration measurements. It provides six channels of dynamic signal acquisition, and you can use one of four gain settings to configure your input range. The PXIe‑4480 also includes software-configurable AC/DC coupling, charge measurement, voltage excitation, IEPE excitation, and TEDS support, making it ideal for measuring acoustic transducers, pressure sensors, and hydrophones. Common applications include audio test; noise, vibration, and harshness (NVH) analysis; and underwater acoustic measurements. For measuring sudden changes, such as high speed blast and pressure events, the PXIe-4480 can sample up to 20 MS/s per channel in time-domain mode.

  • PXIe-4305, 24-Bit, 32-Channel, 51.2 kS/s, 42 V, PXI Analog Input Module

    783868-01 - NI

    24-Bit, 32-Channel, 51.2 kS/s, 42 V, PXI Analog Input Module—The PXIe‑4305 is a filtered analog input module for higher voltage measurements. The module offers the ability to select a digital filter per channel to provide extra filtering performance. You also can operate up to four different sample rates and triggering configurations concurrently to ensure you measure every sensor as needed. The module has an A/D converter per channel to enable a simultaneous sample rate at the maximum sample rate across the input range. The included NI‑DAQmx driver simplifies hardware configuration and measurement.

  • PXI-4461, 204.8 kS/s, 2-Input/2-Output PXI Sound and Vibration Module

    779687-01 - NI

    204.8 kS/s, 2-Input/2-Output PXI Sound and Vibration Module—The PXI‑4461 is designed for sound and vibration applications. It provides two-channel dynamic signal generation and two-channel acquisition, and you can use one of six gain settings to configure your input range. The PXI‑4461 also includes software-configurable AC/DC coupling and IEPE conditioning. The PXI‑4461 includes the hardware and software needed to make precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications include audio test; automotive noise, vibration, and harshness (NVH); and machine condition monitoring.

  • PXIe-4497, 204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module

    781369-01 - NI

    204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module - The PXIe‑4497 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4497 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4497 delivers simultaneous sample on all channels. In addition, the module includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gain, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.

  • PXIe-4499, 204.8 kS/s, 114 dB, 4 Gains, AC/DC-Coupled, 16-Input PXI Sound and Vibration Module

    781370-01 - NI

    204.8 kS/s, 114 dB, 4 Gains, AC/DC-Coupled, 16-Input PXI Sound and Vibration Module - The PXIe‑4499 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4499 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4499 delivers simultaneous sample on all channels. In addition, the PXIe‑4499 includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.

  • PXIe-4304, 24-Bit, 32-Channel, 5 kS/s, 42 V, PXI Analog Input Module

    783867-01 - NI

    24-Bit, 32-Channel, 5 kS/s, 42 V, PXI Analog Input Module—The PXIe‑4304 is a filtered analog input module for higher voltage measurements. The module offers the ability to select a digital filter per channel to provide extra filtering performance. You also can operate up to four different sample rates and triggering configurations concurrently to ensure you measure every sensor as needed. The module has an A/D converter per channel to enable a simultaneous sample rate at the maximum sample rate across the input range. The included NI‑DAQmx driver simplifies hardware configuration and measurement.

  • PXIe-4340, PXI Displacement Input Module

    785068-01 - NI

    The PXI Displacement Input Module supports 4-, 5-, and 6-wire AC linear variable differential transformer (LVDT) and AC rotary variable differential transformer (RVDT) measurements. The module simultaneously samples each analog input and sets the excitation frequency and voltage for each channel independently. You can set different timing, triggering, and sampling modes for each channel independently. Diagnostic features include self-calibration, overcurrent detection, and open coil detection.The PXI Displacement Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • PXI/PXIe 16-Channel Digital Output Module

    40-412A-024 - Pickering Interfaces Ltd.

    16-Channel Digital Output modules with high output voltage and current capability. The outputs can be used for high or low drive and each channel is capable of sourcing 0.5A from the high side or 0.5A sink on the low side. Accidental operation of both high and low side driver on the same channel is prevented by the supplied driver. Outputs are fully protected against over-voltage, over-current and thermal overload, ensuring robust and reliable operation in the toughest test environments. For high side driving, the voltage source is supplied externally, allowing the module to drive high capacity loads separate from the chassis power supply. For low side driving, the external source is not used and the module’s output operates an open collector or open drain driver.

  • Digital Output

    VME-2170A - Abaco Systems Inc

    The VME-2170A optically coupled digital output board consists of VMEbus compatibility logic,data control logic, four 8-bit output registers, and 32 optically isolated high-level outputs. The board is implemented as a double Eurocard form factor PC board, and provides all necessary address decoding and data transfer control logic to accept both 8- and 16-bit data transfers. Optical couplers isolate the 32 outputs from each other and from the VMEbus.